Specifications



Stabilizer

 SNO
PARAMETERS SINGLE PHASE THREE PHASE
1.
Input Voltage 170 – 270 Volts 300 – 460 Volts
2.
Output Voltage 230 Volts 400 Volts
3.
Output Voltage Adjust 220 – 240 Volts 380 – 420 Volts
4.
Frequency 47 – 53 Hz 47 – 53 Hz
5.
Voltage Correction 35 V/Sec 35 V/Sec.
6.
Voltage Accuracy +/- 1 % Volts +/-1 % Volts
7.
Cooling Mode

Air Cooled

Air/Oil Cooled
8.
Servo Motor Synchronous Synchronous
9.
Environment

Indoor Temperature

Indoor Temp
10.
Wave Form Sine Wave Sine Wave
11.
Product Range 1 – 25 KVA 3 – 1000 KVA

SAILIENT FEATURES:


Stabilizer Cabinet is fully Powder Coated.
Built – in Voltmeter to Monitor Input / Output Voltages.
Auto / Manual mode of Operations are available.
Electronic Automatic High / Low Voltage Cut-off facility is available.
Proper Indications for Input / Output.
Single Phasing Prevention facility is available in 3 Phase Servo.
Suitable MCB (or) H.R.C Fuses are available for Over Load and Sort Circuit Protection.
Special Input Range 140- 240 Volts & 245 – 465 Volts are available.
Special Technical Design Stabilizers are available.

ONLINE UPS

1.
Output Wave form

Sine wave

2.
Input Characteristics

Single Phase  170 – 270 V 
Three Phase  380 – 460 V AC

3.
Frequency 50 Hz
4.
INVERTER 
 
  • Output voltage
  • Frequency
  • Load Power Factor
  • Harmonic Distortion
  • Duty Cycle
  • Cooling
230 V AC ,  400 V AC
50 Hz
0.8 Lag Unity
5%
Continuous
Forced Air
5.
OUTPUT CHARACTERISTICS 
 
  • Voltage
  • Frequency
  • Battery Voltage
  • Production
230 V AC
50 Hz
48/72/96/120/240/360/384
MCB Trips, HRC Fuses, Electronic Logic Control for Input Output, Inverter & Battery
6.
Alarm Audio Alarms for Low Battery Annunciation & Electronic Trip
7.
Metering AC Volts, DC Volts
8.
Indications

Mains On, Inverter On  Battery Low, Battery High

9.
Push Switch Start, Stop, Re Set
10.
Operating Conditions MOC, Relative Humidity 95%
11.
Technology High Performance IGBT
12.
Capacity 1 KVA to 1000 KVA

Inverter
1.
Mains Input

170 V to 250 V

2.
Frequency 50 Hz
3.
Back Up Times 30 Minutes to 10 Hours
4.
Change over times Less than 2 ms
5.
Charger SCE with Trickle Charging
6.
Input Power Battery 12 V, 24 V, 48 V, 120 V, 180 V
7.
Capacity

500 VA, 750 VA, 1000 VA
2 KVA TO 20 KVA

8.
Production

Over Load Protection
Low Battery Protection
Short Circuit Protection
Over Charge Protection

9.
Indication

Mains On, Inverter On
Battery Low, Over Load



Online UPS, Invertors, Servo Stabilizers, CVT's, Automatic Stabilizers, Emergency lights & Transformers